Choose your language:简体中文English

Currencies:



Search:


Due to the coming of Spring Festival, we will be closed from Feb. 9 to Feb. 25.
You can place the order from the shop as usual. But the delivery of your order will be processed until Feb. 26. For any enquiry during this period, please send email to us, we will check the mail occasionally.
We are sorry for any inconvinence caused. Thank you for your support.

Notice: The freight fee we have setted is DHL fee.If you need other cheaper transportation,please contact us and we will calculate for you.

(Considering the customs problem,for the Brazil customers,we will use EMS instead of DHL or UPS.)


PC/MPI+:RS232 isolated Siemens S7-300/400 PLC Programming adapte

$93.00  $91.14
Save: 2% off

optoelectronic isolated RS232/MPI,Siemens S7-300/400 PLC Programming adapter cable,with communication indicator,can replace Siemens 6ES7 972-0CA23-0XA0,automatically adjust the communication speed from 19.2Kbps to 115.2Kbps for the PC port,automatically adjust the communication speed from 19.2Kbps to 187.5Kbps for the MPI interface.Can connect PLC and the touch panel of third party factory to communicate.It doesn't support profibus function.

   PC/MPI+ adapter, or named PC adapter, could achieve the level conversion of RS232 to RS485 and the protocal conversion of RS232 to MPI(MultiPoint Interface).

    PC/MPI+ is the adapter of photoelectric isolation type towards industrial design. Between RS232 port and RS485 port exist the surge protection and anti-lightning protection circuit, adaptable to the full PLC series of Siemens S7-300/400 and those devices with MPI port, especially the industrial fields with greater interference and easily damaged communication port. All kinds of protection measures in the circuit give promission to the safe operation of the system.

    PC/MPI+ can make touch-screen communications with the third party under the link of S7-300/400PLC, such as eView, Wei-lun and kun-lun state.

Characteristics and main technical parametres:

★ Power: It is supplied by the 24VDC MPI port of PLC, power consumption of about 1w, with overcurrent protection and surge protection.

★ Isolation Voltage: 1000VDC(Maximun to 3000 VDC, orders require statement.)

★ RS232 port has anti-surge protection, RS485 port has anti-lightning protection and overcurrent protection with the consumption of 500w.

★ RS232 port baud rate: 19.2Kbps---115.2Kbps, automatically adaptable to the standard baud rate.

★ MPI port baud rate: 187.5Kbps---19.2Kbps, automatically adaptable.

★ Supporting the connection of PLC to touch-screen communication with the third party.

★ With a power indicater light, on-line and data transmission indicater light.

★ Working temperature: -20~75℃

★ Dimension: 103×50×26; After connecting the RS232 cables: 5.5m.

RS232 adapter port and port-pin RS485 signal definations:

RS232-Block(DB9M) defination signals           RS485-Block(DB9M) defination signals

Pin number

Signal name

Instructions

 

Pin number

Signal name

Instructions

1

DCD

No use

1

NC

No use

2

RXD

RS232 signal reception

2

M24V

Negtive 24VDC power

3

TXD

RS232 signal sending

3

B

RS485 positive signal

4

DTR

Short circuit with No.6

4

RTSAS

Data reception control

5

GND

RS232 signal to ground

5

GND

RS485 signal to ground

6

DSR

Short cut with No.4

6

NC

No use

7

RTS

Sending requsts

7

P24V

24VDC positive power

8

CTS

Sending clear

8

A

RS485 negtive signal

9

RI

No use

9

RTS_PG

Data-send control

 

Instructions of the indicater light

Indicater light

On

Qlittering

Out

Power

Normal

Error

Error or failing to link to power

Active

Online

Transmission of data

Not online

Tx

Error

Send data

No data transmission

 

Software settings of STEP7:

    Entering the main interface of STEP7 programming software(SIMATIC Manager), clicking on “Options” menu under the “Set PG/PC Interface…” option into the PG/PC interface settings.

1.    Double clicking on “PC Adapter(MPI)” into the RS232 interfaces and MPI set of parameters. The adapter does not support “PC Adapter(PROFIBUS)” option.

2.    Clicking on “Local Connection” option set RS232 interface parameters, choosing PC/MPI to connect on the port of COM correctly, and it will adapt to the chosen baud rate automatically, both 19200bps and 38400bps of RS232 communication.

3.    Clicking “MPI” to set port parameters of adapter MPI, acceptable at both 187.5Kbps and 19.2Kbps, and the adapter will adapt to its baud rate automatically. Others have already been set.

4.    On-line test accessing point: Using PC/MPI to connect to MPI port and RS232 port of the computer. And then click on the button in the red circle as follow, if appearing the data inside the red line, the test has passed. Then one could operate on it.

The long-distance communication of PC/MPI+ adapter:

1. To extend the distance of RS485 port:

 

 

2. To extend the distance of RS232 port:

 

RS232 Cable:

When you buy PC/MPI+,we will give you the free RS232 Cable.

The quality is guaranteed.It's tested before shippment.Not made by Siemens,OEM product as the replacement.


After you place the order on line,pls contact us and we will calculate the freight fee for you according to your requirements.

The item will be delivered within 3-5 working days once payment is received and cleared.Please pay within 3 days after your order.

If you need large quantity(more than 20PCS),Pls contact us and we will give you the competitive wholesale price.


Add to Cart:

  • Model: PC/MPI+


This product was added to our catalog on Thursday 13 November, 2008.

Customers who bought this product also purchased...